Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Adicionar filtros








Intervalo de ano
1.
Chinese Journal of Cardiology ; (12): 615-620, 2021.
Artigo em Chinês | WPRIM | ID: wpr-941326

RESUMO

Objective: To investigate the clinical and electrophysiological features of ventricular tachycardia (VT) in tetralogy of Fallot (TOF) patients post surgical repair (rTOF) and to analyze the therapeutic effect and prognosis of radiofrequency ablation of rTOF-VT. Methods: This is a retrospective study. Consecutive patients with rTOF-VT, who were treated in Fuwai Hospital from January 2015 to March 2020, were enrolled. All the patients underwent right ventricular voltage mapping following routine cardiac electrophysiological examination, followed by linear or homogenizing radiofrequency ablation based on the low-voltage substrate. The clinical features, 3-dimentional electrophysiological substrate mapping, radiofrequency ablation and long-term prognosis of the enrolled patients were analyzed. Acute ablation success was defined as completion of linear or homogenizing ablation or intraoperative evoked VT as destination of the procedure. Patients were followed up at 3 and 6 months post operation and every year thereafter. The endpoints were sudden cardiac death (SCD) and recurrence of ventricular tachycardia. Results: A total of 20 patients with rTOF-VT were enrolled including 14 males with an age of (35.8±11.8) years. The electrocardiogram identified 23 types of ventricular tachycardia, 19 of which were originated from right ventricular inflow tract outlet. The most common clinical manifestations were heart murmur (19 cases, 95%) and syncope (4 cases, 25%). Electroanatomical substrate mapping was performed in 20 patients and evidenced localized or diffuse scar or low-voltage area of right ventricle. Intraoperative electrophysiological tests provoked ventricular tachycardia in 6 patients (30%), including 5 patients with hemodynamics disturbance. The acute success rate of radiofrequency ablation was 95% (19/20). The follow-up time was (31.1±17.7) months and the recurrence rate of ventricular tachycardia was 30% during follow-up period and 5 cases received repeat radiofrequency ablation and there was no recurrent ventricular tachycardia during follow-up post repeat radiofrequency ablation. Conclusions: The voltage substrate mapping under sinus rhythm is a feasible mapping method for rTOF-VT. Linear or flaky radiofrequency ablation of the slow conduction zone is safe and effective treatment strategy, the recurrence rate after the first radiofrequency ablation is still high, and the effectiveness of repeat radiofrequency ablation is satisfactory in this patient cohort.


Assuntos
Adulto , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Arritmias Cardíacas , Ablação por Cateter , Eletrocardiografia , Seguimentos , Estudos Retrospectivos , Taquicardia Ventricular/cirurgia , Tetralogia de Fallot/cirurgia , Resultado do Tratamento
2.
Chinese Journal of Cardiology ; (12): 224-228, 2021.
Artigo em Chinês | WPRIM | ID: wpr-941265

RESUMO

Objective: To define the current status and analyze the medical quality of interventional therapy for patients with atrial fibrillation (AF) in China. Methods: This survey was performed in all seven large regions of China, one to three regional major medical centers were selected from each region. Medical records of patients underwent interventional therapy for AF in the year 2017 were randomly inspected. CHA2DS2-VASc score, prescribed anticoagulant after ablation, indication of left atrial appendage occlusion (LAAO), and complications in the medical records were analyzed. Results: A total of 10 800 AF catheter ablations and 447 LAAOs were performed in 17 regional medical centers in 2017. There were 10/17 centers performing AF catheter ablation<500 cases and 7/17 centers performing LAAO<20 cases. A total of 1 347 cases of catheter ablation and 160 cases of LAAO were selected for further analysis. Among all selected cases, 15.8% (238/1 505) non-valvar AF cases recorded CHA2DS2-VASc scores. The anticoagulation rate after AF catheter ablation was 98.6% (1 328/1 347), anticoagulation rate was higher than 90% in 16 out of 17 centers. The complication and severe complication rates of AF catheter ablation were 0.9% (12/1 347) and 0.4% (5/1 347), respectively. The differences of complication and severe complication rates in AF catheter ablation were similar between centers performing<500 cases and centers performing ≥500 cases (0.5% (2/413) vs. 1.1% (10/934), P>0.05; 0.5% (2/413) vs. 0.3% (3/934), P>0.05). The coincidence rate of LAAO indication was 81.3% (130/160), and the rate was higher in center performing ≥20 cases than in centers performing<20 cases (84.8% (106/125) vs. 68.6% (24/35), P<0.05). The complication and severe complication rates of LAAO were 3.1% (5/160) and 1.9% (3/160). The rate of complications in LAAO was higher in center performing<20 cases than in centers performing ≥20 cases (8.6% (3/35) vs. 1.6% (2/125), P<0.05), and there was no significant difference in severe complication rate (5.7% (2/35) vs. 0.8% (1/125), P>0.05). Conclusions: Interventional therapy for AF in China is generally standardized and safe. The overall incidence of complications post AF interventional ablation is low, the anticoagulation rate after AF catheter ablation is high, and the adherence rate of LAAO indication is fair. The indicators mentioned above vary widely among centers.

3.
Chinese Medical Journal ; (24): 1151-1153, 2015.
Artigo em Inglês | WPRIM | ID: wpr-350336

RESUMO

<p><b>BACKGROUND</b>Nonfluoroscopic three-dimensional electroanatomical system is widely used nowadays, but X-ray remains indispensable for complex electrophysiology procedures. This study aimed to evaluate the value of optimized parameter setting and different projection position to reduce X-ray radiation dose rates.</p><p><b>METHODS</b>From June 2013 to October 2013, 105 consecutive patients who underwent complex ablation were enrolled in the study. After the ablation, the radiation dose rates were measured by two different settings (default setting and optimized setting) with three projection positions (posteroanterior [PA] projection; left anterior oblique [LAO] 30° projection; and LAO 45° projection). The parameter of preset voltage, pulse width, critical voltage, peak voltage, noise reduction, edge enhancement, pulse rate, and dose per frame was modified in the optimized setting.</p><p><b>RESULTS</b>The optimized setting reduced radiation dose rates by 87.5% (1.7 Gy/min vs. 13.6 Gy/min, P < 0.001) in PA, 87.3% (2.5 Gy/min vs. 19.7 Gy/min, P < 0.001) in LAO 30°, 85.9% (3.1 Gy/min vs. 22.1 Gy/min, P < 0.001) in LAO 45°. Increase the angle of projection position will increase the radiation dose rate.</p><p><b>CONCLUSIONS</b>We can reduce X-ray radiation dose rates by adjusting the parameter setting of X-ray system. Avoiding oblique projection of large angle is another way to reduce X-ray radiation dose rates.</p>


Assuntos
Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Arritmias Cardíacas , Cirurgia Geral , Fibrilação Atrial , Cirurgia Geral , Ablação por Cateter , Métodos , Eletrofisiologia , Fluoroscopia , Métodos , Doses de Radiação
4.
Chinese Medical Journal ; (24): 1450-1454, 2015.
Artigo em Inglês | WPRIM | ID: wpr-231756

RESUMO

<p><b>BACKGROUND</b>Current evidence links atrial fibrillation (AF) to the inflammation. Inflammatory indexes such as high-sensitive C-reactive protein (hs-CRP) have been related to the development and persistence of AF. However, the role of inflammation in the atrial electrophysiological remodeling indexed by P-wave dispersion (P d ) remains unclear.</p><p><b>METHODS</b>The study consisted of 71 patients with lone paroxysmal AF (AF group) and 71 age- and gender-matched controls of paroxysmal supraventricular tachycardia without history of AF (control group). Electrocardiography, P d , hs-CRP, and other clinical characteristics were compared between the two groups.</p><p><b>RESULTS</b>There was no significant difference between the two groups regarding age, gender, hyperlipidemia, etc. Compared to controls, left atrial diameter (44 ± 7 vs 39 ± 7 mm), P d (49 ± 13 vs 26 ± 8 ms), and hs-CRP (2.17 [1.46-2.89] vs 1.12 [0.74-1.41] mg/L) were increased (P < 0.05), respectively. Linear regression identified hs-CRP as an independent correlation of P d level both in the total population and the AF group (r = 0.464 and 0.313; P < 0.001, respectively). Multiple logistic regression revealed hs-CRP as an independent determinant of AF (odds ratio [OR] =15.430, 95% confidence interval: 6.031-39.476: P <0.001). Further adjusted for P d , both P d and hs-CRP were independent predictors for AF, but the OR for hs-CRP in predicting AF has been attenuated from 15.430 to 6.246.</p><p><b>CONCLUSIONS</b>In lone AF, P d and plasma hs-CRP concentration are inter-associated and related to AF. The interaction between hs-CRP and AF may be mediated by P d , suggesting an important role of inflammation in the atrial electrophysiological remodeling predisposing to AF.</p>


Assuntos
Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fibrilação Atrial , Metabolismo , Proteína C-Reativa , Metabolismo
5.
Chinese Journal of Nuclear Medicine ; (6): 97-100, 2011.
Artigo em Chinês | WPRIM | ID: wpr-643049

RESUMO

Objective To analyze alterations in electrocardiogram (ECG) of adenosine test in 99Tcm-MIBI myocardial perfusion imaging(MPI)SPECT study. Methods A total of 641 patients were in cluded in the study. The patients each underwent 99Tcm-MIBI MPI with adenosine test. The ECGs were taken before, during, and after adenosine infusion. Results In all, abnormal ECGs were found in 205(32.0%) patients. During adenosine infusion, 20.6%(132/641) of patients suffered from arrhythmia,29.5%(39/132) had atrial premature beats, 34. 1% (45/132) had premature ventricular beats, and 6. 1% (8/132) had sinoatrial block. In addition, 5.3% (7/132) had first-, 24.2% (32/132) had second-, and 0.8%(1/132) had third-degree atrioventricular block (AVB). After adenosine infusion, 4.4%( 28/641) of patients suffered from arrhythmia, 57.1% (16/28) had atrial premature beats, 39.3%(11/28) had premature ventricular beats, and 3.6% (1/28) had sinoatrial block. The perfusion images showed ischemia in 36 patients and infarction in 8 patients. Adenosine infusion was terminated in 39 patients (6. 1%) because of poorly tolerated side effects. However, no death or acute myocardial infarction occurred in the study. Conclusions Adenosine pharmacologic test for 99TcmMIBI MPI may result in relatively high incidence of arrhythmia in ECG monitoring.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA